Improved internal model control technique for position control of AC servo motors. ELEKTRIKA- Journal of Electrical Engineering, 19 (1). pp. 17-25. ISSN 0128-4428 (2020)
Abstract
This paper focuses on the simulation analysis of the conventional Internal Model Control (IMC) technique and the development of two proposed control techniques for the position control of AC Servo Motor. Internal Model Control (IMC)technique [1] was only able to control the AC Servo Motor under static load condition. Also, it had step response problems, and it was not robust against external disturbances. For these reasons, the IMC technique was further improved to control the AC Servo Motor under dynamic load conditions by proposing Amended Internal Model Controller (AIMC). The step response and the robustness of AIMC against external disturbances were further improved by proposing AIMC+FLC. Where a Fuzzy Logic Controller (FLC) is designed and connected with the AIMC.
Item Type: | Article |
---|---|
Keywords: | AC servo motor, AIMC, AIMC+FLC, Control stability, Bode diagram, Dynamic load, External disturbances, IMC, Static load, Step response |
Taxonomy: | By Subject > College of Engineering > Electrical Engineering > Systems By Subject > College of Engineering > Mechanical Engineering > Mechanics |
Local Content Hub: | Subjects > College of Engineering |
Depositing User: | Eza Eliana Abdul Wahid |
Date Deposited: | 02 Dec 2022 04:07 |
Last Modified: | 02 Dec 2022 04:07 |
Related URLs: |
Actions (login required)
View Item |